This integration connects Shelly Wi-Fi devices directly to the nomos system controller – no Shelly Cloud, no additional bridge. The controller configures the device itself when it is added: from then on the device reports directly to the controller and can be used like any other device in rooms, scenes and automations.

Both device generations are supported – the classic first generation as well as the current Plus, Pro and Gen3 models. Among them: relays and plugs, dimmers and lights (including RGBW), roller shutter actuators, energy meters, radiator thermostats, and the battery-powered sensors and buttons (door/window, temperature/humidity, smoke, motion, Button).

WARNING

Before you begin: The Shelly must already be on your Wi-Fi and in the same network as the controller. Bring new devices into the network first, using the Shelly app or the access point the device opens by itself.

Adding a device:

  1. Enable the integration:
    • Switch the Shelly skill on. The skill page then shows the list of connected devices.
  2. Pick the device:
    • Click Add Device. The controller searches the network and lists the Shellys it finds, each with its identifier and address; devices that were already added are marked as such.
    • If a device does not announce itself – because mDNS is switched off, or it sits in a different network segment – enter its IP address by hand.
  3. Credentials:
    • If the device is password-protected, the dialog asks for the login. On the newer generations the username is fixed to admin; on the first generation it is freely chosen.
  4. Shelly Cloud notice (first generation only):
    • First-generation firmware holds either the connection to the Shelly Cloud or the one to the controller – not both at once. From the moment the device is added, nomos is what reaches it from outside your home; the Shelly app still finds it inside your own network, but no longer over the internet.
  5. Name and room:
    • Optionally assign a name – without one, the name the device carries itself is used – and pick the room.
  6. Add:
    • Adding takes up to half a minute: the device is reconfigured, reboots, and has to report back to the controller.

INFO

Battery-powered devices sleep. Wake the device right before adding it – for the Button a single press is enough, sensors have a small button on the case – so the controller can configure it. Afterwards these devices report whenever they wake on their own; battery level and readings update at that rhythm.

WARNING

"Another component already addresses this device": This warning appears when an older component in the controller – for example one imported from a manually installed addon profile – already addresses the same device. Two components on one device switch each other. Continue only if you are going to delete the other component afterwards.

The overview:

Each row shows the device's name, its identifier (it ends in the MAC address, which is also printed on the device), model and generation, and the IP address – clicking it opens the device's own web interface in a new tab. To the right sit the components created from the device; a device with several channels has several. The banner at the top sums up the state of all devices.

When a device reports a problem:

A message underneath the device says what is wrong; Repair re-runs the setup against the stored – or a corrected – address:

  • "The device is not reporting to the broker." – The device is currently unreachable, for example powered off or out of Wi-Fi range. Once it reports back, the message clears on its own.
  • "Setup was interrupted …" – An earlier add did not run to completion. Repair catches up on the missing steps.
  • "MQTT was switched off on the device." – The connection to the controller was disabled on the device itself, on the first generation for example by re-enabling the Shelly Cloud. Repair restores it.
  • "The stored login is no longer accepted." – The device's password was changed. Repair asks for the new credentials.
  • "The device cannot be reached under its stored address." – The device received a new IP address. Enter it under Repair.

INFO

Tip: Give Shelly devices a fixed IP address in your router (DHCP reservation). A changed address is the most common reason for a device suddenly being listed as unreachable.

Removing a device:

The × in the device row removes a device. Its components are deleted from rooms, scenes and automations, and its access to the controller is revoked. The device itself stays on your Wi-Fi and keeps working on its own – through its switches and its web interface.